奥的斯ACD系列通用最新故障码(下)
使用服务器M1-1-2-1查看到的所有故障记录,所有事件类别分为I/W/F/EIInformation信息
WWaring警告
FFault错误
EElite - Visible only in the ALL Menu Event Trace
savedRuns从上次送电到现在的运行次数
savedMins从上次送电到现在的时间(单位:分钟)
故障代码
故障名称
类别
故障解释
相关设置
System
0600
SPB-Alert
W
服务面板检测到一个错误,需要手动救援SPB 和 SDI。可能的原因有:SDI 的错误的速度编码器
SPB 上缺陷的 E2PROM
SPB 上的电池缺失
按SPB 按钮,REB+DDO 同时,以定位错误源
控制板检测到 SPB 和 SDI 故障. Ssk 可能的原因有:1.编码器故障2.SPB 上的 E2 存储器故障3.电池故障同时按 SPB 上的 REB+DDO 定位故障原因Error # 1, encoder A failure (only ...AAA/...AAB)Error # 2, encoder B failure (only ...AAA/...AAB)Error # 4, E2Prom failureError # 5, battery failureError # 12, 3 encoder A failureError # 13, received out of range parameters fromTCBC/GECB /RCBII
0601
SPB:TempHTS
W
服务面板过热。
SPB-Temp
0602
LwssService
W
称重板请求REM。参见称重板故障原因。称重系统请求服务
0603
Aro Service
W
The ARO subsystem (modified SPBC_III) requested “Request For Service” (REM). See ARO
subsystem’s event logging for reason.
0604
S/WChanged
I
软件变更。SCN 更改
0605
Update S/W!
F
升级软件!要求更新 GECB 软件
0606
SpbService
W
SPB 请求服务
0607
/TUM1
F
TUM1 missing after run at TOP or active during standstill; (reduced overhead: trig- ger modulcontacts)
TUM1(1047)
HWY-TYP
0608
/TUM2
F
TUM2 missing after run at TOP or active during standstill; (reduced overhead: trig- ger modulcontacts)
TUM2(1048)
HWY-TYP
0609
/TDM
F
TDM missing after run at BOTTOM or active during standstill; (shallow pit: trig- ger modul contacts)
TDM(1049)
HWY-TYP
0610
/TUPS
F
TUPS missing during run; (reduced overhead: trigger modul power supply)
TUPS(1050)
HWY-TYP
0611
/TDPS
F
TDPS missing during run; (shallow pit: trigger modul power supply)
TDPS(1051)
HWY-TYP
0612
SOS up
F
Safety Operated Switch Up triggered
SOSU(1054)
HWY-TYP
0613
SOS down
F
Safety Operated Switch Down triggered
SOSD(1055)
HWY-TYP
0614
PRBB BatLow
W
The battery of the PRBB board is weak: During PowerOff, the battery only pro- vides power for
less than 10 seconds.
EN-PRBB=1
0615
PCB Certi
W
The PCB certification is not performed by using OEK PDA until the specified days expired. In order
that this function is ap- plied, it should be set by OEK PDA. Note: only for Korea application
0616
C-circuit
F
C-circuit does not work correctly
Note: only for MCS310
C-CHK (704)
0617
RBU-Selftst
F
Selftest of Rope Brake has failed (i.e. lasted longer than 5 seconds).
Car is blocked until TCI/ERO is switched.
RBTC (1029)
RBTE (1028)
0618
RBU-Fault
F
Rope Brake has detected overspeed. Car is blocked until TCI/ERO is switched.
RBTC (1029)
RBTE (1028)
0619
HWY-TYP
F
Please refer to blinking message “LOPIT cfg!”
Low Pit
0626
DeepBattery
F
LVA Switch or Evolux: Deep Discharge Protection switched off the OCB to pro- tect the batteries
(voltage was < 40 VDC).
GECB-LV DRV-TYP
0627
LowBat wait
F
LVA Switch or Evolux: Enforced Battery Charging
GECB_LV DRV-TYP
0628
NoPowerWait
F
LVA Switch or Evolux: BatRun-T expired during blackout
GECB-LV DRV- TYP
BatRun-T
0629
HighBatWait
F
LVA Switch: Enforced Battery Discharg- ing
Battery voltage exceeded 70 VAC.
GECB-LV
0630
OverBat
F
LVA Switch: Overvoltage Protection is going to switch off the OCB to protect the batteries
(voltage > 75 VDC).
GECB-LV
0631
E2P Mapped
I
The LCB2/TCBC E2Prom data, provided by an E2TB (E2prom Transfer Board) were mapped to the
GECB layout
event
0701
SP missing
F
Node Guarding does not detect the SP at the CAN bus. Check CAN_OK LED at SP;
Check CAN wiring between GECB & SP;
0702
BCB missing
F
Node Guarding does not detect the 1st BCB at the CAN bus. Check CAN_OK LED at LVPB/BCB_II
Check CAN wiring between GECB & LVPB/BCB_II
0703
BcbIoFail
F
The state of inputs was not received eve- ry second or the output command was not acknowledged.
CAN bus overload?
Defect LVPB/BCB_II?
0704
BcbHwFail
F
The BCB published an EEPROM error.
Exchange LVPB/BCB_II
0705
BcbSwFail
F
The BCB published a task timing prob- lem.
See subcode ‘x’ for details
Exchange LVPB/BCB_II according to subcode
0706
EncoderFail
F
The rescue encoder generates no signals during a normal run. Check rescue encoder wiring;
Replace rescue encoder or GECB_II;
0707
OCB fail
F
The OCB auxiliary contacts are wired incorrectly. Check wiring to OCB;
Check OCB;
Check GECB_II inputs;
0708
Overspeed
W
The measured rescue encoder speed is 15% faster than the nominal speed. The OS contact or the safeties could be acti- vated. MRO is prevented.
Reset OS contact;
Check Encoder / Speed parameter;
SPEED
Encoder
0709
MRO_BRK Flt
F
A wrong voltage at the brake was detect- ed.
That means that the brake could be unin- tentionally lifted during MRO. Check input MRO_BRK and wiring of the brake
Check LVPB / Replace LVPB
DO NOT PERFORM MRO!!!
LVA
0710
No Battery
F
The 1st BCB misses the rescue battery.
Check RPS / battery
0711
BatTempErr
W
The 1st BCB indicates that the battery cannot be charged, because the tempera- ture is out of range.
Check battery temperature sensor
注:删除单个故障:服务器 GO ON 或者 GO BACK 选中将要删除的故障
SHIFT(蓝健) + 1 (ON) 然后 SHFIT + CLEAR (ENTER) 当前单个故障删除
新版本有 M1-1-2-7菜单,代替了SHIFT(蓝健)+UP(2 )
页: